Avigilon GE Facility Commander Wnx Integration Manual de usuario Pagina 11

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 13
  • Tabla de contenidos
  • SOLUCIÓN DE PROBLEMAS
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 10
Avigilon Control Center System Integration Guide with GE Facility Commander Wnx
8
4. Click Add Mapping.
5. Repeat step 3 and 4 until all the alarms you require are mapped.
6. Click Save.
Backing Up Mapped Alarms
After you finish mapping all the alarms in the Avigilon FCWnx Gateway, you can choose to back
up a copy of the mappings.
1. Navigate to C:\Program Files\Avigilon\Avigilon FCWnx Gateway\.
NOTE: The filepath may be different depending on how your system is configured.
2. Copy and paste the GatewayParams.xml file to a back up location.
Restoring Mapped alarms
When you have a backup copy of the mapped alarms, you can restore the integration to use the
back up copy any time.
1. Open the Avigilon FCWnx Gateway configuration application to stop the Gateway
Windows service.
2. Locate your backup copy of the GatewayParams.xml file.
3. Copy and paste the backup GatewayParams.xml file into the C:\Program
Files\Avigilon\Avigilon FCWnx Gateway\ folder.
Allow Windows to overwrite the copy that is currently in the folder.
4. Close the Avigilon FCWnx Gateway configuration application to start the Gateway
Windows service.
5. To check if the mapped alarms were restored correctly, open the Avigilon FCWnx
Gateway configuration application again.